Release Notes 2.1.4
Release Date: October 16, 2018
What's New
New in this release:
- HIPclient for Android
- With this release, the HIPclient is available for Android. Your Android devices can now natively connect to your IDN overlay, giving them a trusted and verifiable connection wherever you are. Multiple profiles allow you to easily switch between different IDN overlays as needed.
- Improved Conductor UI Navigation
- Several UI elements have been redone to improve navigation:
- Conductor settings are now accessed from the gear icon in the upper right corner of the UI.
- The logged in user profile, API docs, EULA, and sign-out are accessed from the user account icon in the upper right corner of the UI.
- Item names in many lists throughout the UI now actively link to properties pages and dialogs. This greatly simplifies navigation between related elements.
- Tags
- Tags provide flexible asset management in the Conductor. Devices, Device
Groups, HIPswitches, HIPswitch Groups, Overlay Networks, and People can be
tagged directly. The Tag information dialog allows you to
Navigate directly to any tagged item, perform
bulk Actions (Enable, Disable, or Untag tagged
items), and edit Properties. Items can be tagged
permanently or until you untag them. You can also set an expiration date,
which will untag a component after a configurable period of time. You can
create tags from the Tags page, access from the tag
icon in the upper right corner of the UI.
You can also create tags inline while modifying an item’s tag members by entering a new tag name and select colors for easy classification. Tags have been integrated into searching and filtering throughout Conductor.
Tags can be used in matching rules to greatly simplify Smart Device Groups. They can also be added to or removed from taggable items in Event Monitor Actions, which allows monitor results to affect overlay network policies. By using tags with these features, you can optimize your workflows. For example, you can create temporary network policies for specific devices, easily revoke policy directly from devices or HIPswitches without having to navigate to a network, and allow multiple admins to keep track of their assets in a single Conductor.
- Relay Probes
- A HIPswitch with this option selected will periodically send probe packets to all of its relays, and use the closest relay when initiating secure tunnels. This reduces the amount of network traffic used to build new tunnels, and allows auto-connect to be turned off. You can find this option in the Advanced settings section of a HIPswitch's settings page.
- Conductor Diagnostics
-
Similar to diagnostics offered for HIPswitches, the Conductor now has a set of maintenance and diagnostic functions consolidated under the Diagnostics tab of the Settings page. These include Creation or Restoration of a DB Backup, downloading a Conductor support bundle, and viewing a Conductor diagnostic report. Network diagnostics allow you to generate a packet capture on the Conductor interface, ping, and traceroute.
Upgrade Considerations
The 2.1.4 release includes all hotfixes from prior releases and addresses all known support cases at the time of release.
We recommend you upgrade to 2.1.4 if: | |
---|---|
You want to take advantage of performance and stability increases in 2.1, especially for any of the following features:
|
You were impacted by any issues discovered in prior releases, especially if you have any of the following:
|
Extensive testing was conducted both in-house and with selected development partners, in lab and in production environments to ensure that performance is equivalent to 2.1.3. Additionally, 2.1.4 should be more stable than all prior releases.
Enhancements
Applies to | Description |
---|---|
Conductor, API | Added a new node in the API, /api/v1/email_settings, containing methods for setting, updating, and retrieving Conductor email settings. |
HIPclient, Windows | The HIPclient for Windows has received the following improvements:
|
HIPclient, macOS | The HIPclient on macOS has received the following improvements:
|
HIPclient, Windows and macOS | Updated the HIPclient UI to allow you to double-click a profile in the configuration dialog to make a profile active. |
Fixes
ID | Applies to | Description |
---|---|---|
DEV-8849 | HIPswitch | Fixed an issue on the HIPswitch 250 where using 100BASE-FX mode on port 8 could cause phantom link events. |
DEV-8699 | HIPclient, Linux | Fixed an issue where 32-bit platforms would drop MAP connections after a certain amount of network traffic. |
DEV-8221 | OpenHIP | Fixed an issue where changing the default UDP port under | in the Conductor was not respected by 2.1.3 HIPswitches.
DEV-8142 | Conductor | Fixed an issue where clicking Finish two times very quickly when upgrading Conductor firmware would cause the upgrade to fail. |
DEV-8198 | Licensing | Fixed an issue where some email clients would insert additional lines in the encrypted_synced_package.json file and prevent the file from uploading to the Conductor correctly. |
DEV-8120 | HIPswitch, Azure | Fixed an issue where in rare cases, an Azure HIPswitch may fail to reconnect to the Conductor after a firmware upgrade. |
DEV-8119 | Conductor | Fixed an issue where a reactivated HIPclient configured with an overlay IP was listed as two devices, and you were unable to remove the overlay IP. |
DEV-8067 | HIPswitch | Fixed an issue that caused overlay device NAT to fail if more than one device port was used, or if the port was configured as a VLAN. |
DEV-8049 | Conductor | Fixed an issue where a network administrator may be able to view a HIPswitch group while restricted from viewing some of the HIPswitches in the group. |
DEV-7962 | HIPclient, Windows | Fixed an issue where upon waking, a computer in sleep mode would cause the HIPservice to stop and start, taking 30-60 seconds to recover. |
DEV-7959 | HIPswitch 100 | Fixed an issue where configuring a VLAN tag on a HIPswitch 100 would cause currently active tunnels to stop working. |
DEV-7913 | Conductor | Fixed a UI error when creating a new Cloud HIPservice where the dialog box message would display Network create completed incorrectly when the deployment creation failed. |
DEV-7814 | HIPclient, Windows | Fixed an issue where a user name was not retained between failed log in attempts. |
DEV-6881 | HIPswitch | Fixed an issue where the LCD panels on the HIPswitch 500 and Conductor 500 displayed messages incorrectly. |
DEV-6507 | Conductor | Fixed an issue where the throughput graph for a HIPservice would occasionally miss a data point and display it as a zero value. |
DEV-6172 | Conductor | Fixed an issue where a HIPclient would incorrectly show the underlay IP as the overlay IP when it did not have an overlay IP set. They now correctly display they are NAT devices in the overlay IP column. |
DEV-5448 | Conductor | Fixed an issue where navigating to an HA-paired secondary HIPswitch would allow you to select the Swap Roles option and cause the UI to stop responding. |
DEV-5428 | Conductor UI | Fixed an issue where creating a Smart Device Group with Ignore auto-discovered devices until accepted checked and then removing the setting would cause the Smart Device Group to continue ignoring unaccepted devices. |
DEV-5343 | Conductor UI | Fixed an issue where trying to log in after a session has timed
out would generate the following error: The change you wanted was rejected. |
DEV-4548 | HIPswitch | HIPswitches now support 802.1p tagged traffic when using VLAN-tagged traffic in overlay networks. |
DEV-4537 | Conductor | Fixed an issue where the UI would not update correctly when demoting a master Conductor to standby. |
Known Issues
ID | Applies to | Description |
---|---|---|
DEV-9157 | HIPclient, macOS | Killing the hipctl daemon
(tnw-cltd) will result in the HIPclient
not functioning properly. If you try and run any hipctl commands, the message Could not connect with Tempered Networks control process is displayed. No message is displayed when trying to make changes from the configuration UI. Workaround: Restart the process by entering sudo launchctl start com.temperednetworks.ctld from the terminal. |
DEV-9081 | HIPclient, macOS (El Capitan) | The HIPclient on macOS 10.11, El Capitan, does not provide the
necessary cryptographic APIs to create and use a private key from
the Keychain. Instead, the HIPclient for macOS will detect this case
and store the private key in its own storage. Workaround: To take advantage of the added protection using the Keychain, upgrade to macOS 10.12 (Sierra) or higher and create a new HIPclient profile. |
DEV-8188 | HIPswitch | A HIPswitch in transparent mode will not update the version
information reported in the Conductor UI. This causes upgrade issues
from 1.12.x to 2.x. Workaround: Disable transparent mode for the HIPswitch. This updates the version information. You can then perform a firmware upgrade. |
DEV-8122 | Conductor | When creating o modifying a cloud HIPservice, the
Name and Network
name fields do not check for the presence of invalid
characters. This will be fixed in a later
release. Workaround: Do not include
|
DEV-8097 | HIPclient, macOS | If your computer has multiple active NICs and you select a
specific NIC in your HIPclient configuration, the operating system
will choose the NIC for outbound traffic. Workaround: None |
DEV-8060 | Conductor | In rare cases, a Conductor HA pair will stop
syncing. Workaround: If this happens, promote the HA-secondary to a primary, then re-pair them. |
DEV-8051 | Conductor | The IP address field on associated with a HIPswitch may be blank
on the HIP Services tab. Workaround: You can locate the IP address information under the Reporting tab. |
DEV-7955 | Conductor | If you ping a HIPswitch running in Azure from another HIPswitch,
it will fail in the Conductor UI. This is due to ICMP being denied
by Azure's security groups. Workaround: None |
DEV-7814 | HIPclient, Windows | If user authentication fails, your user name is not retained and
you must re-enter it. Workaround: None |
DEV-7769 | Conductor | Toggling policy on and off too quickly on a HIPswitch hosted in
Google Cloud can result in the route table becoming out of sync when
using route injection. Workaround: After toggling policy, wait 10 seconds before toggling it again. |
DEV-7661 | Conductor | When replacing a HIPswitch, the new HIPswitch may take a few
minutes to reconnect and appear online in the
Conductor. Workaround: Wait a few minutes after replacing the HIPswitch for it to display in the Conductor UI. |
DEV-7499 | HIPswitch | The bandwidth check in the HIPswitch
Diagnostics tab might fail for HA-paired
HIPswitches. Workaround: None |
DEV-7125 | Conductor, PCI | When exporting PCI data, HIP Services references may not display
correctly when viewing the CSV file in Microsoft
Excel. Workaround: None |
DEV-7058 | HIPswitch | When reconfiguring your underlay network from one physical port
to another in the Conductor, the changes may not be applied
successfully and the configuration will revert back to the original
settings. Workaround: Make the configuration changes in diagnostic mode. |
DEV-6590 | Conductor | You can add a voucher code more then once from the
Licensing tab. This does not create
additional licenses, but is visually confusing. This will be fixed
in a later release. Workaround: None |
DEV-6587 | Conductor | The Licensing tab may display invalid
entries. Workaround: Remove the invalid items manually. |
DEV-6533 | Conductor | When creating or editing a smart device group, rules can have the
same ordinal values. This can cause unintended issues in the
processing results. Workaround: When creating rules, verify each rule has a unique ordinal value. |
DEV-6446 | HIPclient, iOS | When viewing traffic stats in the iOS app, the chart may show
negative values instead of zero. Workaround: None |
DEV-6226 | Conductor | A fully qualified domain name cannot be used for local or peer
replication addresses on an HA Conductor pair. Workaround: None |
DEV-6195 | Conductor | The Conductor incorrectly displays an option to check bandwidth
for HIPclients in diagnostic view. This option is not supported for
HIPclients and will not function correctly if
selected. Workaround: None |
DEV-6118 | AWS | The Forgot my password link can send an
invalid Conductor location. Workaround: Replace the location in the link with the correct Conductor address. |
DEV-5832 | HIPswitch | Device NAT functionality currently does not work with layer 2
traffic. Workaround: None |
DEV-5530 | Conductor UI | In some cases, Allow incoming pings (ICMP)
and SYN Flood Protection on the
Firewall page may be disabled and won't
toggle. Workaround: Refresh your browser to resolve the issue. |
DEV-5430 | Conductor | After configuring a Conductor for the first time, you may receive
a Lost connection to the original server
message if you select Return to settings too
quickly. Workaround. Wait at least 20 seconds before selecting Return to settings. |
DEV-5008 | PCI Reporting | PCI Reporting shows the UUID reference instead of the name when
generating a PCI report from Workaround: To view names, you can download object references from the same page where you generated the PCI report. |
.
DEV-2417 | Conductor UI | The password reset email link defaults to the first web enabled
interface, and will be successful only if an administrator
configures the first interface with a publicly-facing default route.
Workaround: None. |
DEV-1846 | Conductor, HA | The standby Conductor UI in an HA pair will not timeout. This
issue does not affect the master Conductor UI. Workaround: Log off manually when not using the standby Conductor UI. |